Z-MED™ Percutaneous Transluminal Valvuloplasty catheter
INDICATIONS
- Recommended for Percutaneous Transluminal Valvuloplasty (PTV) for mitral and aortic positions. The use of this catheter is particularly indicated in stenosis where difficulty in balloon positioning during inflation is experienced.
- Recommended for Percutaneous Transluminal Valvuloplasty (PTV) of the pulmonary valve.
- A patient with isolated pulmonary stenosis.
- A patient with valvular pulmonary stenosis with other minor congenital heart disease that does not require surgical intervention.
The Z-MED™ high pressure dilatation catheter is a coaxially constructed catheter with a distally mounted non-compliant high pressure balloon. The catheter exhibits a comparable profile to other marketed catheters by also combines this profile with a high pressure balloon suitable for resistant stenosis. The Z-MED™ balloon catheter is available in over 50 configurations ranging in diameter from 2.0 to 40.0 mm.
- General
- Specifications
-
Catheter Characteristics
The Z-MED™ high pressure dilatation catheter is a coaxially constructed catheter with a distally mounted non-compliant high pressure balloon. The catheter exhibits a comparable profile to other marketed catheters by also combines this profile with a high pressure balloon suitable for resistant stenosis. The Z-MED™ balloon catheter is available in over 50 configurations ranging in diameter from 2.0 to 40.0 mm.
Radiopaque Marker
Platinum marker bands facilitate reliable positioning of the balloon.
Balloon
The Z-MED™ PTV balloon has a low deflated profile that maintains tip flexibility. The exceptionally low profile balloon requires the smallest introducer possible. Nominal dimensions are maintained over the entire length of the balloon.
Maximum Trackability
The distal shaft through the balloon is highly flexible for exceptional maneuverability. This, combined with the pushability of the coaxial shaft, provides outstanding tracking performance.
-
Product specifications
Balloon
Diameter
(MM)Balloon
Length
(CM)Introducer
Size
(FR)Shaft
Size
(FR)Usable
Length
(CM)Guide
Wire
(Inches)Rated
Burst
(ATM)Catalog
No.22.0 6.0 12 9 100 0.035 3 SO006 22.0 8.0 12 9 100 0.035 3 SO081 23.0 2.0 12 9 120 0.035 3 SO052 23.0 3.0 12 9 120 0.035 3 SO058 23.0 4.0 12 9 120 0.035 3 SO047 23.0 5.0 12 9 100 0.035 3 SO016 24.0 2.0 12 9 75 0.035 3 SO084 24.0 4.0 12 9 100 0.035 3 SO059 24.0 5.0 12 9 100 0.035 3 PDZ397 24.0 6.0 12 9 85 0.035 3 SN031 25.0 3.0 12 9 85 0.035 3 PDZ384 25.0 3.0 12 9 100 0.035 3 SO056 25.0 3.0 12 9 120 0.035 3 SO057 25.0 4.0 12 9 85 0.035 3 PDZ313 25.0 4.0 12 9 100 0.035 3 PDZ339 25.0 5.0 12 9 100 0.035 3 PDZ362 25.0 5.0 12 9 120 0.035 3 PDZ346 25.0 6.0 12 9 100 0.035 3 PDZ374 25.0 8.0 12 9 100 0.035 3 SO082 26.0 2.0 12 9 100 0.035 3 SO061 26.0 3.0 12 9 75 0.035 3 SO085 26.0 4.0 12 9 75 0.035 3 SO063 26.0 4.0 12 9 100 0.035 3 SO060 28.0 2.0 12 9 85 0.035 2 SO043 28.0 2.0 12 9 120 0.035 2 SO053 28.0 3.0 12 9 85 0.035 2 SO027 28.0 3.0 12 9 120 0.035 2 SO050 28.0 4.0 12 9 75 0.035 2 SO064 28.0 4.0 12 9 85 0.035 2 PDZ315 28.0 4.0 12 9 100 0.035 2 PDZ387 28.0 4.0 12 9 120 0.035 2 SO046 30.0 2.0 14 9 85 0.035 2 SO041 30.0 2.0 14 9 120 0.035 2 SO054 30.0 3.0 14 9 85 0.035 2 SO026 30.0 3.0 14 9 120 0.035 2 SO051 30.0 4.0 14 9 75 0.035 2 SO062 30.0 4.0 14 9 85 0.035 2 PDZ316 30.0 4.0 14 9 120 0.035 2 SO055 30.0 6.0 14 9 85 0.035 2 PDZ393 30.0 6.0 14 9 100 0.035 2 PDZ394 30.0 8.0 14 9 100 0.035 2 SO083 33.0 4.0 16 11 100 0.035 1.5 SO073 33.0 6.0 16 11 100 0.035 1.5 SO074 35.0 4.0 16 11 100 0.035 1.5 SO075 35.0 6.0 16 11 100 0.035 1.5 SO076 40.0 4.0 16 11 100 0.035 1 SO077 40.0 6.0 16 11 100 0.035 1 SO078