Coefficient™ Pediatric Valvuloplasty catheter
Recommended for Percutaneous Transluminal Valvuloplasty (PTV) of the pulmonary valve in pediatric applications.
- A patient with isolated pulmonary stenosis.
- A patient with valvular pulmonary stenosis with other minor congenital heart disease that does not require surgical intervention.
The COEfficient™ Pediatric Valvuloplasty catheter is engineered for maximum steering and tracking. The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability.
- General
- Specifications
-
Catheter Characteristics
The COEfficient™ Pediatric Valvuloplasty catheter is engineered for maximum steering and tracking. The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability.
Radiopaque Marker
Platinum marker bands facilitate reliable positioning of the balloon.
Balloon
The COEfficient™ Pediatric Valvuloplasty balloon has a low deflated profile that maintains tip flexibility. The exceptionally low profile balloon requires the smallest introducer possible. Nominal dimensions are maintained over the entire length of the balloon.
Maximum Trackability
The distal shaft through the balloon is highly flexible for exceptional maneuverability. This, combined with the pushability of the coaxial shaft, provides outstanding tracking performance.
-
Product specifications
Balloon
Diameter
(MM)Balloon
Length
(CM)Introducer
Size
(FR)Shaft
Size
(FR)Usable
Length
(CM)Guide
Wire
(Inches)Rated
Burst
(ATM)Catalog
No.4.0 2.0 4 3.5 75 0.018 13 COE101 4.0 2.0 4 3.5 135 0.018 13 COE128 4.0 3.0 4 3.5 75 0.018 13 COE102 4.0 4.0 4 3.5 75 0.018 13 COE103 5.0 2.0 4 3.5 75 0.018 12 COE104 5.0 2.0 4 3.5 135 0.018 12 COE129 5.0 3.0 4 3.5 75 0.018 12 COE105 5.0 4.0 4 3.5 75 0.018 12 COE106 6.0 2.0 5 3.5 75 0.018 12 COE107 6.0 2.0 5 3.5 135 0.018 12 COE130 6.0 3.0 5 3.5 75 0.018 12 COE108 6.0 4.0 5 3.5 75 0.018 12 COE109 7.0 2.0 5 3.5 75 0.018 11 COE110 7.0 2.0 5 3.5 135 0.018 11 COE131 7.0 3.0 5 3.5 75 0.018 11 COE111 7.0 4.0 5 3.5 75 0.018 11 COE112 8.0 2.0 6 3.5 75 0.018 10 COE113 8.0 2.0 6 3.5 135 0.018 10 COE132 8.0 3.0 6 3.5 75 0.018 10 COE114 8.0 4.0 6 3.5 75 0.018 10 COE115 9.0 2.0 6 3.5 75 0.018 10 COE116 9.0 3.0 6 3.5 75 0.018 10 COE117 9.0 4.0 6 3.5 75 0.018 10 COE118 10.0 2.0 6 3.5 75 0.018 10 COE119 10.0 3.0 6 3.5 75 0.018 10 COE120 10.0 4.0 6 3.5 75 0.018 10 COE121 11.0 2.0 6 3.5 75 0.018 8 COE122 11.0 3.0 6 3.5 75 0.018 8 COE123 11.0 4.0 6 3.5 75 0.018 8 COE124 12.0 2.0 6 3.5 75 0.018 7 COE125 12.0 3.0 7 3.5 75 0.018 7 COE126 12.0 4.0 7 3.5 75 0.018 7 COE127 The devices listed have CE mark approval. Any customer or distributor outside of the EU will be subject to their individual country's regulations in regards to the importation and sale of these products.
This publication could include technical or other inaccuracies or typographical errors. Changes are periodically added to the information herein; these changes will be incorporated in the new editions of the publication. NuMED Incorporated may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time.