Z-MED-X™ Percutaneous Transluminal Valvuloplasty catheter
Recommended for Percutaneous Transluminal Valvuloplasty (PTV) of the pulmonary valve.
- A patient with isolated pulmonary stenosis.
- A patient with valvular pulmonary stenosis with other minor congenital heart disease that does not require surgical intervention
Our X-Line catheters exhibit several special features:
- Xtra high inner lumen strength
- Xtra fast guidewire movement (even with balloon inflated)
- Increased pushability from new braided inner tubing
- Radiopaque inner tubing
- Specifications
-
Product specifications
Balloon Diameter (MM) Balloon
Length
(CM)Introducer
Size
(FR)Shaft
Size
(FR)Usable
Length
(CM)Guide
Wire
(Inches)Rated
Burst
(ATM)Catalog
No.8 2 7 6 100 0.035 10.0 PDZ400 8 3 7 6 100 0.035 10.0 PDZ401 8 4 7 6 100 0.035 10.0 PDZ402 8 5 7 6 100 0.035 10.0 PDZ403 8 6 7 6 100 0.035 10.0 PDZ404 9 2 7 6 100 0.035 10.0 PDZ405 9 3 7 6 100 0.035 10.0 PDZ406 9 4 7 6 100 0.035 10.0 PDZ407 9 5 7 6 100 0.035 10.0 PDZ408 9 6 7 6 100 0.035 10.0 PDZ409 10 2 7 6 100 0.035 9.0 PDZ410 10 3 7 6 100 0.035 9.0 PDZ411 10 4 7 6 100 0.035 9.0 PDZ412 10 5 7 6 100 0.035 9.0 PDZ413 10 6 7 6 100 0.035 9.0 PDZ414 12 2 7 6 100 0.035 7.0 PDZ415 12 3 7 6 100 0.035 7.0 PDZ416 12 4 7 6 100 0.035 7.0 PDZ417 12 5 7 6 100 0.035 7.0 PDZ418 12 6 7 6 100 0.035 7.0 PDZ419 14 3 8 7 100 0.035 6.0 PDZ420 14 4 8 7 100 0.035 6.0 PDZ421 14 5 8 7 100 0.035 6.0 PDZ422 14 6 8 7 100 0.035 6.0 PDZ423 15 3 8 7 100 0.035 5.0 PDZ424 15 4 8 7 100 0.035 5.0 PDZ425 15 5 8 7 100 0.035 5.0 PDZ426 15 6 8 7 100 0.035 5.0 PDZ427 16 3 9 7 100 0.035 5.0 PDZ428 16 4 9 7 100 0.035 5.0 PDZ429 16 5 9 7 100 0.035 5.0 PDZ430 16 6 9 7 100 0.035 5.0 PDZ431 18 3 10 8 100 0.035 4.0 PDZ432 18 4 10 8 100 0.035 4.0 PDZ433 18 5 10 8 100 0.035 4.0 PDZ434 18 6 10 8 100 0.035 4.0 PDZ435 20 3 11 8 100 0.035 4.0 PDZ436 20 4 11 8 100 0.035 4.0 PDZ437 20 5 11 8 100 0.035 4.0 PDZ438 20 6 11 8 100 0.035 4.0 PDZ439 22 3 11 9 100 0.035 3.0 PDZ440 22 4 11 9 100 0.035 3.0 PDZ441 22 5 11 9 100 0.035 3.0 PDZ442 22 6 11 9 100 0.035 3.0 PDZ443 25 3 12 9 100 0.035 3.0 PDZ444 25 4 12 9 100 0.035 3.0 PDZ445 25 5 12 9 100 0.035 3.0 PDZ446 25 6 12 9 100 0.035 3.0 PDZ447 28 3 12 9 100 0.035 2.0 PDZ448 28 4 12 9 100 0.035 2.0 PDZ449 28 5 12 9 100 0.035 2.0 PDZ450 28 6 12 9 100 0.035 2.0 PDZ451 30 3 13 9 100 0.035 2.0 PDZ452 30 4 13 9 100 0.035 2.0 PDZ453 30 5 13 9 100 0.035 2.0 PDZ454 30 6 13 9 100 0.035 2.0 PDZ455 The devices listed have CE mark approval. Any customer or distributor outside of the EU will be subject to their individual country's regulations in regards to the importation and sale of these products.
This publication could include technical or other inaccuracies or typographical errors. Changes are periodically added to the information herein; these changes will be incorporated in the new editions of the publication. NuMED Incorporated may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time.