Z-MED II™ Percutaneous Transluminal Valvuloplasty catheter
INDICATIONS
- Recommended for Percutaneous Transluminal Valvuloplasty (PTV) for mitral and aortic positions. The use of this catheter is particularly indicated in stenosis where difficulty in balloon positioning during inflation is experienced.
- Recommended for Percutaneous Transluminal Valvuloplasty (PTV) of the pulmonary valve.
- A patient with isolated pulmonary stenosis.
- A patient with valvular pulmonary stenosis with other minor congenital heart disease that does not require surgical intervention.
The Z-MED II™ dilatation catheter provides higher pressure and in some instances a larger introducer than the Z-MED™. The coaxial haft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability. The Z-MED II™ ballon catheter is available in configurations ranging from 4.0 to 30.0 mm in diameter.
- General
- Specifications
-
Catheter Characteristics
The Z-MED II™ dilatation catheter provides higher pressure and in some instances a larger introducer than the Z-MED™. The coaxial haft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability. The Z-MED II™ balloon catheter is available in configurations ranging from 4.0 to 30.0 mm in diameter.
Radiopaque Marker
Platinum marker bands facilitate reliable positioning of the balloon.
Maximum Trackability
The distal shaft through the balloon is highly flexible for exceptional maneuverability. This, combined with the pushability of the coaxial shaft, provides outstanding tracking performance.
-
Product specifications
Ballon
Diameter
(MM)Ballon
Lengte
(CM)Introducer
Afmeting
(FR)Schacht
Afmeting
(FR)Bruikbare
Lengte
(CM)Voer-
draad
(Inches)Nominale
Ontlading
(ATM)*Nominale
Druk
(ATM)Catalogus
Nr.10.0 6.0 7 6 100 0.035 13 6 PDZ634 11.0 2.0 8 6 120 0.035 10 6 SN044 11.0 3.0 8 6 100 0.035 10 6 SO028 11.0 4.0 8 6 100 0.035 10 6 SO039 12.0 2.0 8 6 100 0.035 10 6 PDZ635 12.0 2.0 8 6 120 0.035 10 6 SN045 12.0 2.5 8 6 100 0.035 10 6 SO068 12.0 3.0 8 6 100 0.035 10 6 PDZ636 12.0 4.0 8 6 100 0.035 10 6 PDZ637 12.0 5.0 8 6 100 0.035 10 6 PDZ638 12.0 6.0 8 6 100 0.035 10 6 PDZ639 14.0 2.0 9 7 100 0.035 10 5 PDZ681 14.0 2.0 9 7 120 0.035 10 5 SN046 14.0 3.0 9 7 100 0.035 10 5 PDZ640 14.0 4.0 9 7 100 0.035 10 5 PDZ641 14.0 5.0 9 7 100 0.035 10 5 PDZ642 14.0 6.0 9 7 100 0.035 10 5 PDZ643 15.0 3.0 9 7 100 0.035 8 5 PDZ644 15.0 4.0 9 7 100 0.035 8 5 PDZ645 15.0 5.0 9 7 100 0.035 8 5 PDZ646 15.0 6.0 9 7 100 0.035 8 5 PDZ647 16.0 3.0 9 7 100 0.035 8 4 PDZ648 16.0 4.0 9 7 100 0.035 8 4 PDZ649 16.0 5.0 9 7 100 0.035 8 4 PDZ650 16.0 6.0 9 7 100 0.035 8 4 PDZ651 18.0 3.0 10 8 100 0.035 7 4 PDZ652 18.0 4.0 10 8 100 0.035 7 4 PDZ653 18.0 5.0 10 8 100 0.035 7 4 PDZ654 18.0 6.0 10 8 100 0.035 7 4 PDZ655 20.0 3.0 12 8 100 0.035 5 2 PDZ656 20.0 4.0 12 8 100 0.035 5 2 PDZ657 20.0 4.5 11 10 110 0.035 5 2 PDZ678 20.0 5.0 12 8 100 0.035 5 2 PDZ658 20.0 6.0 12 8 100 0.035 5 2 PDZ659 22.0 3.0 12 9 100 0.035 4 2 PDZ660 22.0 4.0 12 9 100 0.035 4 2 PDZ661 22.0 4.5 12 10 110 0.035 4 2 PDZ679 22.0 5.0 12 9 100 0.035 4 2 PDZ662 22.0 6.0 12 9 100 0.035 4 2 PDZ663 23.0 3.0 14 9 100 0.035 4 2 PDZ664 23.0 3.0 14 9 120 0.035 4 2 SO044 23.0 4.0 14 9 100 0.035 4 2 PDZ665 23.0 5.0 14 9 100 0.035 4 2 PDZ666 23.0 6.0 14 9 100 0.035 4 2 PDZ667 25.0 2.0 14 9 85 0.035 4 2 SO042 25.0 2.0 14 9 100 0.035 4 2 SO040 25.0 3.0 14 9 100 0.035 4 2 PDZ668 25.0 3.0 14 9 120 0.035 4 2 SO045 25.0 4.0 14 9 100 0.035 4 2 PDZ669 25.0 4.5 12 10 110 0.035 4 2 PDZ680 25.0 5.0 14 9 100 0.035 4 2 PDZ670 25.0 6.0 14 9 100 0.035 4 2 PDZ671 26.0 2.0 14 9 100 0.035 4 2 PDZ672 26.0 4.0 14 9 100 0.035 4 2 SO070 28.0 2.0 16 11 100 0.035 3.5 2 PDZ673 28.0 4.0 16 11 100 0.035 3.5 2 SO071 30.0 2.0 16 11 100 0.035 3 2 PDZ674 30.0 4.0 16 11 100 0.035 3 2 SO072 30.0 5.0 16 11 100 0.035 3 2 SO079 30.0 6.0 16 11 100 0.035 3 2 PDZ675 The devices listed have CE mark approval. Any customer or distributor outside of the EU will be subject to their individual country's regulations in regards to the importation and sale of these products.
This publication could include technical or other inaccuracies or typographical errors. Changes are periodically added to the information herein; these changes will be incorporated in the new editions of the publication. NuMED Incorporated may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time.