NuMED
-
BIB® Stent Placement catheter
An inner balloon 1/2 of the balloon diameter of the outer balloon. i.e. BB010 has an 8.0 mm inner balloon.
View product -
Coefficient™ Pediatric Valvuloplasty catheter
The COEfficient™ Pediatric Valvuloplasty catheter is engineered for maximum steering and tracking. The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability.
View product -
CP Stent™
The CP Stent™ is composed of 0.013" platinum / iridium wire that is arranged in a “zig” pattern, laser welded at each joint and over brazed with 24K gold. It allows expansion from 8.0 mm to 24.0 mm. The Covered CP Stent™ is comprised of the Bare CP Stent that is covered with an expandable sleeve of ePTFE.
View product -
MULLINS-X™ Ultra high pressure dilatation catheter
Our X-Line catheters exhibit several special features: - Xtra high inner lumen strength - Xtra fast guidewire movement (even with balloon inflated) - Increased pushability from new braided inner tubing - Radiopaque inner tubing
View product -
NuCLEUS-X™
Recommended for Percutaneous Transluminal Valvuloplasty (PTV) for mitral and aortic position applications. The use of this catheter is particularly indicated in stenosis where difficulty in balloon positioning during inflation is experienced.
View product -
NuCLEUS™ PTV catheter
The NuMED NuCLEUS™ PTV catheter is engineered for maximum steering and tracking. The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability. The innovative single balloon design facilitates positive positioning while holding the balloon in the correct location prior to and during inflation.
View product -
PTS-X™ Sizing Balloon Catheter
PTS-X™ Sizing Balloon Catheter - Xtra high inner lumen strength - Xtra fast guidewire movement (even with balloon inflated) - Increased pushability from new braided inner tubing - Radiopaque inner tubing
View product -
PTS® Sizing Balloon Catheter
The PTS® Sizing Balloon catheter has been designed for use in patients with cardiovascular defects where accurate measurement of the defect is important to select the appropriately sized occluder device.
View product -
TYSHAK II ® Percutaneous Transluminal Valvuloplasty catheter
The TYSHAK II® catheter is a coaxially constructed catheter with a distally mounted non-compliant balloon. The catheter exhibits an extremely low profile that allows the interventionalist to use the small introducer possible. Due to the coaxial construction, the catheter inflates and deflates extremely fast. The TYSHAK II® catheter provides smaller introducers and in some cases slightly lower burst pressures than the TYSHAK®.
View product -
TYSHAK Mini® Pediatric Valvuloplasty catheter
The TYSHAK Mini® Pediatric Valvuloplasty catheter has been designed and engineered with a super thin balloon of 2.0 or 4.0 cm in usable length along with a 2.5/3.5 Fr shaft and mini distal tip, making the TYSHAK Mini® the lowest profile of any available balloon in its diameter.
View product -
TYSHAK-X™ Percutaneous Transluminal Valvuloplasty catheter
Our X-Line catheters exhibit several special features: - Xtra high inner lumen strength - Xtra fast guidewire movement (even with balloon inflated) - Increased pushability from new braided inner tubing - Radiopaque inner tubing
View product -
TYSHAK® Percutaneous Transluminal Valvuloplasty catheter
The TYSHAK® balloon dilatation catheter is a coaxially constructed catheter with a distally mounted non-compliant balloon. The catheter exhibits an extremely low profile. Due to the coaxial construction, the catheter inflates and deflates extremely fast. The TYSHAK® catheter is available in over 100 configurations with balloon lengths from 1.0 to 10.0 cm and balloon diameter from 2.0 to 25.0 mm.
View product -
Z-5™ Atrioseptostomy catheter
The NuMED Z-5™ Atrioseptostomy catheter is engineered for maximum steering and tracking. The dual lumen shaft design provides pushability, coupled with exceptional pull strength. This new innovation in Atrioseptostomy catheter design is of potential importance in patients who are subject to a small left atrium and in small neonates with congenital heart disease requiring Atrioseptostomy.
View product -
Z-MED II-X™ Percutaneous Transluminal Valvuloplasty catheter
Our X-Line catheters exhibit several special features: - Xtra high inner lumen strength - Xtra fast guidewire movement (even with balloon inflated) - Increased pushability from new braided inner tubing - Radiopaque inner tubing
View product -
Z-MED II™ Percutaneous Transluminal Valvuloplasty catheter
The Z-MED II™ dilatation catheter provides higher pressure and in some instances a larger introducer than the Z-MED™. The coaxial haft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability. The Z-MED II™ ballon catheter is available in configurations ranging from 4.0 to 30.0 mm in diameter.
View product -
Z-MED-X™ Percutaneous Transluminal Valvuloplasty catheter
Our X-Line catheters exhibit several special features: - Xtra high inner lumen strength - Xtra fast guidewire movement (even with balloon inflated) - Increased pushability from new braided inner tubing - Radiopaque inner tubing
View product -
Z-MED™ Percutaneous Transluminal Valvuloplasty catheter
The Z-MED™ high pressure dilatation catheter is a coaxially constructed catheter with a distally mounted non-compliant high pressure balloon. The catheter exhibits a comparable profile to other marketed catheters by also combines this profile with a high pressure balloon suitable for resistant stenosis. The Z-MED™ balloon catheter is available in over 50 configurations ranging in diameter from 2.0 to 40.0 mm.
View product